[3-2022]TrainingDump[Q34-Q51]の実際の質問からのNS0-194証明書

[3-2022]TrainingDump[Q34-Q51]の実際の質問からのNS0-194証明書

この記事を評価する

[3月2022日】TrainingDumpの実際の質問によるNS0-194認証

更新されたNS0-194 Dumps PDF - 190の質問とNS0-194本当の有効なブレインダンプ!

NetAppのNS0-194検査の証明の細部:

受験料 $150 USD
受験登録 パーソンヴュー
質問例 NetApp NS0-194 サンプル問題
試験コード NS0-194 NCSE
期間 90分
合格点 63%

 

NO.34 You observe cyclic redundancy check (CRC) errors on a network port from a node in the cluster.
Which two components would you consider reseating or replacing before you perform actions on the physical port where the errors are reported from the node? (Choose two.)

 
 
 
 

NO.35 Referring to the exhibit.


Which two actions would you perform to address the system alternate-control-path (ACP) connectivity issue shown in the exhibit? (Choose two.)

 
 
 
 

NO.36 Click the Exhibit button at the right.
A customer reports that a node panicked due to a multidisk failure.
While in take over, the customer reviewed the output of the sysconfig -a command and noticed a discrepancy in the shelf stack as shown in the exhibit.

The customer proceeded to examine the power supplies in the stack of shelves; all were functional.
Which step would you take to solve this problem?

 
 
 
 

NO.37 A FAS system that is backed by 7200 RPM drives is experiencing extremely latent writes and slow but less latent reads.

Referring to the exhibit, what are two reasons for this result? (Choose two.)

 
 
 
 

38位 You want to set up a FabricPool between an ONTAP cluster and Google Cloud Storage.
In this scenario, which two components are required to accomplish this task? (Choose two.)

 
 
 
 

NO.39 Referring to the exhibit.


Your customer’s MetroCluster controllers have generated AutoSupport notifications with a “DISK REDUNDANCY FAILED” message.
Referring to the exhibit, which component is causing the problem?

 
 
 
 

40位 A customer is showing disk utilization is at 100% in Active IQ even though there are low protocol operations on the controller. You review the data shown in the exhibit.

In this situation, what should you do?

 
 
 
 

NO.41 You want to map an iSCSI LUN from a NetApp controller.
Which two components are required to accomplish this task? (Choose two.)

 
 
 
 

NO.42 What will be the result of adding all nine spare disks to the aggregate?

 
 
 
 

NO.43 出展する:

A customer receives the AutoSupport message shown below.
”(?] Sat Aug 23 13:00:27 PDT [hostname: env_rngr: callhome.c.fan.fru.fault:error] :
Call home for CHASSIS FAN FRU FAILED: SysFan3 F2 (?] Sat Aug 23 13:00:32
PDT [hostname: env_mgr: monitor.chassisFan.ok:notice]: Chassis fan Sysfan3 F2 is ok”
The output of the sysconfig -a command is shown in the exhibit.
In this scenario, what would you do to solve this problem?

 
 
 
 

NO.44 A customer asks what is the correct way to configure an ONTAP system for multi-tenancy. The customer wants to serve data and also protect data using SnapMirror from tenant A using network A and from tenant B using network B.
In this scenario, which statement is correct?

 
 
 
 

NO.45 A customer has reported an unexplained reboot of an ONTAP node that did not generate a panic string or a core file.
In this scenario, which two sets of logs do you collect to further diagnosis the issue? (Choose two.)

 
 
 
 

NO.46 You want to replicate all volumes of an SVM, including the SVM’s configuration data, to another on an hourly schedule.
Which action should you perform to accomplish this task?

 
 
 
 

NO.47 You receive the error shown below on a FAS2750 HA pair.
Mon Jun 24 00:27:30 UTC [NetappA: scsi_cmdblk_strthr_admin:
scsi.cmd.checkCondition:error]: Unknown device 0a.00.99: Check Condition: CDB
0x12: Sense Data SCSI:hardware error – (0x4 – 0x44 0x0 0x0) (0).
The system is cabled as shown in the exhibit.

What should you do to clear the error?

 
 
 
 

NO.48 Which three techniques are used in ONTAP to improve storage efficiencies? (Choose three.)

 
 
 
 
 

49位 A customer cannot create a new volume from OnCommand System Manager.
Which two clustered Data ONTAP daemons would be at fault in this scenario? (Choose two.)

 
 
 
 

NO.50 After a recent unplanned power outage at the site, the power has been restored and you notice power supply fault messages in the event management system (EMS) log or fault lights on the storage shelves.
Which command would you use to collect information about the problem?

 
 
 
 

NO.51 You need to provide a customer an action plan to update an ONTAP system after a security bulletin has been issued.
In this scenario, how do you accomplish this task?

 
 
 
 

Network Appliance NS0-194 Exam Syllabus Topics:

トピック 詳細
トピック 1
  • データアクセスの問題のトラブルシューティング方法に関する知識を示す
  • データ保護の概念を理解する
トピック 2
  • パフォーマンスの分析方法に関する知識を示す
  • ネットアップのハードウェアとソフトウェアのトラブルシューティング
トピック3
  • ONTAPが外部コンポーネントとどのように相互作用するかを説明する
  • データ保護業務に関する知識を示す
トピック4
  • NetAppシステムのFRUを特定する
  • ONTAPロギング・メカニズムを特定する
トピック5
  • ハイブリッドクラウドソリューションのコンポーネントを特定する
  • ストレージ・ハードウェア技術について説明する

 

100%試験の合格保証で、簡単にNS0-194試験に合格します: https://www.trainingdump.com/NetworkAppliance/NS0-194-practice-exam-dumps.html

返信を残す

メールアドレスが公開されることはありません。 が付いている欄は必須項目です

以下の画像からテキストを入力してください。